Nominal Voltage: 6V
Capacity:
- C20: 12Ah (5.25V, at 25℃)
- Nominal Capacity (C20): 12Ah (5.25V, at 25℃)
- C10: 10.8Ah (5.25V, at 25℃)
Dimensions:
- Length: 151mm
- Width: 50mm
- Height: 95mm
- Total Height: 101mm
Internal Resistance: Approximately 8 mΩ (25℃)
Max Short-duration Discharge Current: 360A (25℃)
Weight: Approximately 1.92kg
Terminals: FO-02 / FO-03 / FO-12
■Features
- Designed with flat plate, GEL electrolyte, and AGM separator technology.
- The GEL electrolyte inside the battery maintains uniformity, ensuring excellent cycle life.
- The GEL electrolyte has a substantial thermal capacity, preventing thermal runaway phenomena.
- Constructed with high-strength ABS material for the container and lid.
- Wide temperature range of application (-15~45℃) with the optimal operating temperature at (20±5℃).
- Leak-proof, safe, and reliable.
- Can be used in a standing or lying position, facilitating transportation and installation.
- Low self-discharge rate.
■Specifications
Nominal Voltage: 6V
Capacity:
- C20: 12Ah (5.25V, at 25℃)
- Nominal Capacity (C20): 12Ah (5.25V, at 25℃)
- C10: 10.8Ah (5.25V, at 25℃)
Dimensions:
- Length: 151mm
- Width: 50mm
- Height: 95mm
- Total Height: 101mm
Internal Resistance: Approximately 8 mΩ (25℃)
Max Short-duration Discharge Current: 360A (25℃)
Weight: Approximately 1.92kg
Terminals: FO-02 / FO-03 / FO-12
■Charging
Using ModeCharging VoltageTemperature CompensationMax Charging Current
- Standby Use: 2.275±0.025V per cell (25℃)-3.3mV/℃ per cell3.6A
- Cyclic Use: 2.45±0.05V per cell (25℃)-5mV/℃ per cell
■Storage
- Batteries should be stored in a dry, clean, and well-ventilated warehouse.
- Avoid direct sunlight and keep away from heat sources (such as radiators, with a distance of over 1 meter).
- Ensure batteries are kept away from any toxic gases and organic solvents.
- The longest storage life is 6 months when the ambient temperature is below 25℃. If the temperature is higher, the longest storage life varies as specified in the table below:
Storage Temperature (℃)Storage Time (Months)
≤256
26~333
34~401
- Batteries should be recharged within the storage period or before use.
- Charging method: Maximum charging current is 3.6A, constant voltage is 2.45±0.05V per cell (25℃); Charging time: 15~20 hours; Temperature compensation coefficient: -5mV/℃ per cell.