Specifications
Nominal Voltage: 12V
Capacity:
- C20: 10.0Ah (at 25℃, 10.5V)
- Nominal Capacity (C20): 10Ah (at 25℃, 10.5V)
- C10: 9.0Ah (at 25℃, 10.5V)
Dimensions:
- Length: 151mm
- Width: 98mm
- Height: 94.5mm
- Total Height: 100mm
Internal Resistance: Approximately 15 mΩ (at 25℃)
Max Short-duration Discharge Current: 300A (at 25℃)
Weight: Approximately 3.48kg
Terminal: FO-02/FO-03/FO-12
■Features
- Designed with flat plate, GEL electrolyte, and AGM separator technology.
- The GEL electrolyte inside the battery maintains uniformity, resulting in excellent cycle life.
- The GEL electrolyte has a large thermal capacity, preventing thermal runaway phenomena.
- Made of high-strength ABS material for the container and lid.
- Wide temperature range of application (-15~45℃), with the optimal operating temperature being (20±5℃).
- Leak-proof, safe, and reliable.
- Can be used standing or lying down, making it convenient for transport and installation.
- Low self-discharge rate.
■Specifications
Nominal Voltage: 12V
Capacity:
- C20: 10.0Ah (at 25℃, 10.5V)
- Nominal Capacity (C20): 10Ah (at 25℃, 10.5V)
- C10: 9.0Ah (at 25℃, 10.5V)
Dimensions:
- Length: 151mm
- Width: 98mm
- Height: 94.5mm
- Total Height: 100mm
Internal Resistance: Approximately 15 mΩ (at 25℃)
Max Short-duration Discharge Current: 300A (at 25℃)
Weight: Approximately 3.48kg
Terminal: FO-02/FO-03/FO-12
■Charge
Using ModeCharging VoltageTemperature CompensationMax Charging Current
- Standby Use: 2.275±0.025V/cell (at 25℃)-3.3mV/℃/cell3.0A
- Cyclic Use: 2.45±0.05V/cell (at 25℃)-5mV/℃/cell
■Storage
- Batteries should be stored in a dry, clean, and well-ventilated warehouse.
- Avoid direct sunlight and keep batteries away from heat sources (such as radiators, with a distance of more than 1 meter).
- Batteries should not come into contact with any toxic gases or organic solvents.
- When the ambient temperature is below 25℃, the longest storage life is 6 months. For higher temperatures, refer to the specified storage life in the table below:
Storage Temperature (℃)Storage Time (Month)
≤256
26~333
34~401
- Batteries should be recharged within their storage life or before use.
- Charging methods: maximum charging current of 3.0A, constant voltage of 2.45±0.05V/cell (at 25℃); charging time: 15~20 hours; temperature compensation coefficient: -5mV/℃/cell.