Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

GEL1240AG-CGB battery 12V4AH-gel battery for solar and wind power systems

Specifications
- Nominal Voltage: 12V
- Capacity at C20: 4.0Ah (10.5V, at 25℃)
- Capacity at C10: 3.6Ah (10.5V, at 25℃)
- Dimensions:
- Length: 90mm
- Width: 70mm
- Height: 101mm
- Total Height: 107mm
- Internal Resistance: Approx. 38 mΩ (25℃)
- Max Short-duration Discharge Current: 120A (25℃)
- Weight: Approx. 1.69kg
- Terminal: FO-02/ FO-03

■Features

- Designed with flat plate, GEL electrolyte, and AGM separator technology.

- The GEL electrolyte inside the battery maintains uniformity, resulting in excellent cycle life.

- The GEL electrolyte has a large thermal capacity, preventing thermal runaway phenomena.

- High strength ABS material used for the container & lid.

- Wide temperature range of application (-15~45℃) with the optimal temperature being (20±5℃).

- Leak-proof, safe, and reliable.

- Can be used standing or lying down, convenient for transportation and installation.

- Low self-discharge rate.

■Specifications

- Nominal Voltage: 12V

- Capacity at C20: 4.0Ah (10.5V, at 25℃)

- Capacity at C10: 3.6Ah (10.5V, at 25℃)

- Dimensions:

  - Length: 90mm

  - Width: 70mm

  - Height: 101mm

  - Total Height: 107mm

- Internal Resistance: Approx. 38 mΩ (25℃)

- Max Short-duration Discharge Current: 120A (25℃)

- Weight: Approx. 1.69kg

- Terminal: FO-02/ FO-03

■Charging

- Using ModeCharging VoltageTemperature CompensationMax Charging Current

- Standby Use2.275±0.025V/cell (25℃)-3.3mV/℃/cell1.2A

- Cyclic Use2.45±0.05V/cell (25℃)-5mV/℃/cell

■Storage

- Batteries should be stored in a dry and clean warehouse with a good ventilation system. Avoid direct sunlight and proximity to heat sources (such as radiators, with a distance greater than 1 meter). Also, avoid exposure to any toxic gas and organic solvent.

- The longest storage life is 6 months when the ambient temperature is less than 25℃. If the ambient temperature is higher, the longest storage life varies as specified in the table below:

  - Storage Temperature (℃)≤2526~3334~40

  - Storage Time (Month)631

- Batteries should be recharged within the storage life or before use.

- Charging methods: maximum charging current of 1.2A, constant voltage of 2.45±0.05V/cell (25℃); Charging time: 15~20 hours; Temperature compensation coefficient: -5mV/℃/cell.