SPECIFICATIONS
- Nominal Voltage: 12V
- C10 Capacity: 180Ah (25℃, 10.5V)
- C5 Capacity: 144Ah (25℃, 10.5V)
- Dimensions:
- Length: 560mm
- Width: 125mm
- Height: 316mm
- Total Height: 316mm
- Internal Resistance: Approx. 3.6 mΩ (25℃)
- Max Short-duration Discharge Current: 3600A (25℃)
- Weight: Approx. 54.50kg
- Terminal: RT-62

■FEATURES

- Special polybasic alloys material for the grid, featuring strong corrosion resistance, a special lead paste formula, advanced plate curing technology, and a long service life.

- AGM valve-regulated sealing technology.

- High-strength ABS material for the container and lid.

- Wide temperature range of application (-15~45℃).

- Optimal operating temperature (20±5℃).

- Long and narrow shape with positive and negative terminals on the same side, facilitating easy installation, monitoring, and maintenance.

- Special protective cover for the post, effectively preventing short circuits between positive and negative terminals.

- Special sealing technology for the post and superior sealing glue to ensure no leakage at the terminals.

- Acid filter and anti-explosion design to minimize acid mist emissions, ensuring safe and reliable operation.

- Special sealing glue for the post to ensure no leakage at the terminals.

■SPECIFICATIONS

- Nominal Voltage: 12V

- C10 Capacity: 180Ah (25℃, 10.5V)

- C5 Capacity: 144Ah (25℃, 10.5V)

- Dimensions:

  - Length: 560mm

  - Width: 125mm

  - Height: 316mm

  - Total Height: 316mm

- Internal Resistance: Approx. 3.6 mΩ (25℃)

- Max Short-duration Discharge Current: 3600A (25℃)

- Weight: Approx. 54.50kg

- Terminal: RT-62

■CHARGE

- Standby Use:

  - Charging Voltage: 2.275±0.025V/cell (25℃)

  - Temperature Compensation: -3.3mV/℃/cell

  - Max Charging Current: 45A

- Cyclic Use:

  - Charging Voltage: 2.45±0.05V/cell (25℃)

  - Temperature Compensation: -5mV/℃/cell

■STORAGE


- Batteries should be stored in a dry and clean warehouse with good air exchange.

- Avoid direct sunlight and proximity to heat sources (such as radiators, with a distance of more than 1 meter).

- Keep batteries away from any toxic gases and organic solvents.

- The longest storage life is 6 months when the ambient temperature is below 25℃. For higher temperatures, refer to the specified chart.

- Batteries should be recharged within the storage life or before use.

  - Charging methods: maximum charging current 45A, constant voltage 2.45±0.05V/cell (25℃); Charging time: 15~20 hours; Temperature compensation coefficient: -5mV/℃/cell.


INQUIRY