SPECIFICATIONS
- Nominal Voltage: 12V
- C10 Capacity: 125Ah (25℃, 10.5V)
- C5 Capacity: 100Ah (25℃, 10.5V)
- Dimensions:
- Length: 551mm
- Width: 109mm
- Height: 240mm
- Total Height: 240mm
- Internal Resistance: Approximately 4mΩ (25℃)
- Max Short-duration Discharge Current: 2500A (25℃)
- Weight: Approximately 37.75kg
- Terminal: RT-53
■FEATURES
- Special polybasic alloys material for the grid, offering strong corrosion resistance.
- Special lead paste formula and advanced plate curing technology ensure a long service life.
- AGM valve regulated sealing technology is employed.
- Container and lid made of high-strength ABS material.
- Wide temperature range of application (-15~45℃), with the best operating temperature being (20±5℃).
- Long and narrow shape with positive and negative terminals on the same side, facilitating installation, monitoring, and maintenance.
- Special protective cover for the post, effectively preventing short circuits between positive and negative terminals.
- Special sealing technology for the post and high-quality sealing glue ensure leak-free terminals.
- Acid filter and anti-explosion design minimize the release of acid mist, ensuring safe and reliable operation.
■SPECIFICATIONS
- Nominal Voltage: 12V
- C10 Capacity: 125Ah (25℃, 10.5V)
- C5 Capacity: 100Ah (25℃, 10.5V)
- Dimensions:
- Length: 551mm
- Width: 109mm
- Height: 240mm
- Total Height: 240mm
- Internal Resistance: Approximately 4mΩ (25℃)
- Max Short-duration Discharge Current: 2500A (25℃)
- Weight: Approximately 37.75kg
- Terminal: RT-53
■CHARGE
- Standby Use:
- Charging Voltage: 2.275±0.025V/cell (25℃)
- Temperature Compensation: -3.3mV/℃/cell
- Max Charging Current: 31.25A
- Cyclic Use:
- Charging Voltage: 2.45±0.05V/cell (25℃)
- Temperature Compensation: -5mV/℃/cell
■STORAGE
- Batteries should be stored in a dry, clean warehouse with good ventilation.
- Avoid direct sunlight and proximity to heat sources (such as radiators, with a distance of more than 1m).
- Keep batteries away from any toxic gas and organic solvent.
- The longest storage life is 6 months at temperatures below 25℃. For higher temperatures, refer to the specified chart.
- Batteries should be recharged within their storage life or before use.
- Charging methods: Maximum charging current of 31.25A, constant voltage of 2.45±0.05V/cell (25℃), charging time of 15~20 hours, and temperature compensation coefficient of -5mV/℃/cell.
Contact: Sales Representative: Mr. Xu
Phone: 19710409880
Tel: 400-1177-032
Email: 19710409880@139.com
Add: CGB-172 Checheng Avenue, Wuhan Economic and Technological Development Zone, Hubei Province, China