SPECIFICATIONS
- Nominal Voltage: 6V
- Capacity:
- C20: 4Ah (25℃, 5.25V)
- Nominal Capacity (C20): 4Ah (25℃, 5.25V)
- C10: 3.6Ah (25℃, 5.25V)
- Dimension:
- Length: 70mm
- Width: 47mm
- Height: 101mm
- Total Height: 106mm
- Weight: Approximately 0.80kg
- Internal Resistance: Approximately 20 mΩ (25℃)
- Max Short-duration Discharge Current: 120A (25℃)
- Terminal Type: FO-02 / FO-03
■ FEATURES
- AGM valve regulated sealing technology ensures safety and reliability.
- High-strength ABS material for container and lid.
- Wide temperature range of application (-15~45℃), with optimal operating temperature at 20±5℃.
- Leak-proof design for safety and reliability.
- Can be used standing or lying down, facilitating transportation and installation.
- High sealed reaction efficiency, with minimal water loss and no need to add distilled water or electrolyte, making it easy to use and maintain.
- Low self-discharge rate ensures long-term storage performance.
■ SPECIFICATIONS
- Nominal Voltage: 6V
- Capacity:
- C20: 4Ah (25℃, 5.25V)
- Nominal Capacity (C20): 4Ah (25℃, 5.25V)
- C10: 3.6Ah (25℃, 5.25V)
- Dimension:
- Length: 70mm
- Width: 47mm
- Height: 101mm
- Total Height: 106mm
- Weight: Approximately 0.80kg
- Internal Resistance: Approximately 20 mΩ (25℃)
- Max Short-duration Discharge Current: 120A (25℃)
- Terminal Type: FO-02 / FO-03
■ CHARGE
- Using Mode:
- Standby Use: Charging Voltage 2.275±0.025V/cell (25℃), Temperature Compensation -3.3mV/℃/cell, Max Charging Current 1.2A
- Cyclic Use: Charging Voltage 2.45±0.05V/cell (25℃), Temperature Compensation -5mV/℃/cell
■ STORAGE
- Batteries should be stored in a dry and clean warehouse with good air exchange.
- Avoid direct sunlight and proximity to heat sources such as radiators.
- Ensure a distance of more than 1m from heat sources.
- Avoid exposure to any toxic gas and organic solvent.
- The longest storage life is 6 months when the ambient temperature is below 25℃.
- If the ambient temperature is higher, refer to the specified chart for variations in storage life.
- Batteries should be recharged within the storage life or before use.
- Charging methods: Maximum Charging Current 1.2A, Constant Voltage 2.45±0.05V/cell (25℃)
- Charging Time: 15~20 hours
- Temperature Compensation Coefficient: -5mV/℃/cell
Contact: Sales Representative: Mr. Xu
Phone: 19710409880
Tel: 400-1177-032
Email: 19710409880@139.com