Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

CB1290MC-CGB battery 12V9AH-Suitable for precision instruments

SPECIFICATIONS
- Nominal Voltage: 12V
- Capacity:
- C20: 9Ah (25℃, 10.5V)
- Nominal Capacity (C20): 9Ah (25℃, 10.5V)
- C10: 8.1Ah (25℃, 10.5V)
- Dimension:
- Length: 136mm
- Width: 77mm
- Height: 133mm
- Total Height: 133mm
- Internal Resistance: Approximately 23 mΩ (25℃)
- Max Short-duration Discharge Current: 270A (25℃)
- Weight: Approximately 3.28kg
- Terminal: FP-37

■ FEATURES

- AGM valve regulated sealing technology;

- High strength ABS material for container & lid;

- Wide temperature scope of application (-15~45℃);

- Best temperature of application (20±5℃);

- No leaking, safe and reliable;

- Standing or lying down for use, convenient for transport and installation;

- High sealed reaction efficiency, little water loss, no need to add distilled water or electrolyte, easy to use and maintain;

- Low self-discharge rate.

■ SPECIFICATIONS

- Nominal Voltage: 12V

- Capacity:

  - C20: 9Ah (25℃, 10.5V)

  - Nominal Capacity (C20): 9Ah (25℃, 10.5V)

  - C10: 8.1Ah (25℃, 10.5V)

- Dimension:

  - Length: 136mm

  - Width: 77mm

  - Height: 133mm

  - Total Height: 133mm

- Internal Resistance: Approximately 23 mΩ (25℃)

- Max Short-duration Discharge Current: 270A (25℃)

- Weight: Approximately 3.28kg

- Terminal: FP-37

■ CHARGE

Using ModeCharging VoltageTemperature CompensationMax Charging Current

- Standby Use: 2.275±0.025V/cell (25℃)-3.3mV/℃/cell2.7A

- Cyclic Use: 2.45±0.05V/cell (25℃)-5mV/℃/cell

■ STORAGE

- Batteries should be stored in a dry and clean warehouse with a good air exchange system. They should be kept away from direct sunlight and heat sources (such as radiators, with a distance of more than 1m). Batteries should also be kept away from any toxic gases and organic solvents.

- If the ambient temperature is less than 25℃, the longest storage life is 6 months. However, if the ambient temperature is higher, the longest storage life varies as specified in the chart below:

  Storage Temperature (℃)Storage Time (Month)

  - ≤256

  - 26~333

  - 34~401

- Batteries should be recharged within the storage life or before use. The charging method involves a maximum charging current of 2.7A, constant voltage of 2.45±0.05V/cell (25℃), a charging time of 15~20 hours, and a temperature compensation coefficient of -5mV/℃/cell.


INQUIRY