Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

CB12900-CGB battery12V90AH-Suitable for precision instruments

SPECIFICATIONS
- Nominal Voltage: 12V
**Capacity:**
- C10: 90Ah (10.5V, at 25℃)
- Nominal Capacity (C10): 90Ah (10.5V, at 25℃)
- C5: 72Ah (10.5V, at 25℃)
**Dimension:**
- Length: 304mm
- Width: 168mm
- Height: 208mm
- Total Height: 229mm
**Internal Resistance:** Approx. 6.5 mΩ (25℃)
**Max Short-duration Discharge Current:** 1800A (25℃)
**Weight:** Approx. 30.17kg
**Terminal:** FP-16, FP-17/FP-24/RT-07

**■FEATURES**

- AGM valve regulated sealing technology;

- High strength ABS material for container & lid;

- Wide temperature scope of application (-15~45℃);

- Best temperature of application (20±5℃);

- No leaking, safe and reliable;

- Standing or lying down for use, convenient to transport and install;

- High sealed reaction efficiency, little loss of water, no need to add distilled water or electrolyte, simple to use and maintain;

- Low self-discharge rate.

**■SPECIFICATIONS**

- Nominal Voltage: 12V

**Capacity:**

- C10: 90Ah (10.5V, at 25℃)

- Nominal Capacity (C10): 90Ah (10.5V, at 25℃)

- C5: 72Ah (10.5V, at 25℃)

**Dimension:**

- Length: 304mm

- Width: 168mm

- Height: 208mm

- Total Height: 229mm

**Internal Resistance:** Approx. 6.5 mΩ (25℃)

**Max Short-duration Discharge Current:** 1800A (25℃)

**Weight:** Approx. 30.17kg

**Terminal:** FP-16, FP-17/FP-24/RT-07

**■CHARGE**

**Using Mode**   **Charging Voltage**   **Temperature Compensation**   **Max Charging Current**

- Standby Use: 2.275±0.025V/cell (25℃), -3.3mV/℃/cell, 27A

- Cyclic Use: 2.45±0.05V/cell (25℃), -5mV/℃/cell

**■STORAGE**

- Batteries should be stored in a dry and clean warehouse with a good air exchange system. They should avoid direct sunlight and proximity to heat sources such as radiators (maintain a distance of more than 1m). Additionally, batteries should be kept away from any toxic gases and organic solvents.

- When the ambient temperature is below 25℃, the longest storage life is 6 months. If the ambient temperature is higher, the longest storage life varies as specified in the chart below:

  | **Storage Temperature (℃)** | ≤25  | 26~33 | 34~40 |

  |--------------------------|-------|---------|---------|

  | **Storage Time (Month)**     | 6     | 3       | 1       |

- Batteries should be recharged within their storage life or before using. Charging methods: maximum charging current 27A, constant voltage 2.45±0.05V/cell (25℃); Charging time: 15~20h; Temperature compensation coefficient: -5mV/℃/cell.


INQUIRY