CB12500-CGB battery12V50AH-Suitable for precision instruments

SPECIFICATIONS**
- Length: 229mm
- Width: 138mm
- Height: 207mm
- Total Height: 228mm
- Nominal Voltage: 12V
- Capacity:
- C10: 50Ah (at 25℃, 10.5V)
- Nominal Capacity (C10): 50Ah (at 25℃, 10.5V); C5: 40Ah (at 25℃, 10.5V)
- Internal Resistance: Approximately 10 mΩ (at 25℃)
- Max Short-duration Discharge Current: 1000A (at 25℃)
- Weight: Approximately 16.20kg
- Terminal: FP-22/ FP-14, FP-15/RT-38

**■FEATURES**

- AGM valve regulated sealing technology.

- High strength ABS material for container & lid.

- Wide temperature scope of application (-15~45℃).

- Best temperature of application (20±5℃).

- No leaking, safe and reliable.

- Can be used standing or lying down, convenient to transport and install.

- High sealed reaction efficiency, little loss of water, no need to add distilled water or electrolyte, simple to use and maintain.

- Low self-discharge rate.

**■SPECIFICATIONS**

**■DIMENSION**

- Length: 229mm

- Width: 138mm

- Height: 207mm

- Total Height: 228mm

**■TERMINAL**

- Nominal Voltage: 12V

- Capacity:

  - C10: 50Ah (at 25℃, 10.5V)

  - Nominal Capacity (C10): 50Ah (at 25℃, 10.5V); C5: 40Ah (at 25℃, 10.5V)

- Internal Resistance: Approximately 10 mΩ (at 25℃)

- Max Short-duration Discharge Current: 1000A (at 25℃)

- Weight: Approximately 16.20kg

- Terminal: FP-22/ FP-14, FP-15/RT-38

**■CHARGE**

**Using Mode** **Charging Voltage** **Temperature Compensation** **Max Charging Current**

- Standby Use: 2.275±0.025V/cell (25℃), Temperature Compensation: -3.3mV/℃/cell, Max Charging Current: 15A

- Cyclic Use: 2.45±0.05V/cell (25℃), Temperature Compensation: -5mV/℃/cell

**■STORAGE**

- Batteries should be stored in a dry and clean warehouse with good air exchange system.

- Avoid direct sunlight and proximity to heat sources (such as radiators, with a distance of more than 1m).

- Avoid contact with any toxic gases and organic solvents.

- When the ambient temperature is below 25℃, the longest storage life of the battery is 6 months. If the ambient temperature is higher, the longest storage life of the battery varies as specified in the table below:

  | Storage Temperature (℃) | ≤25  | 26~33 | 34~40 |

  |--------------------------|------|--------|--------|

  | Storage Time (Month)     | 6    | 3      | 1      |

- Batteries should be recharged within the storage life or before use. Charging methods include a maximum charging current of 15A, constant voltage of 2.45±0.05V/cell (25℃), charging time of 15~20 hours. The temperature compensation coefficient is -5mV/℃/cell.