Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

CB12400FG-CGB battery12V40AH-Suitable for precision instruments

Specifications**
**Battery Capacity:**
- C10: 40Ah (at 25℃, 10.5V)
- Nominal Capacity (C10): 40Ah (at 25℃, 10.5V); C5: 32Ah (at 25℃, 10.5V)
**Dimension:**
- Length: 196mm
- Width: 165mm
- Height: 170mm
- Total Height: 170mm
**Internal Resistance:** Approximately 8 mΩ (at 25℃)
**Max Short-duration Discharge Current:** 800A (at 25℃)
**Weight:** Approximately 14.59kg
**Terminal:** FP-28/RT-19

**■Features**

- AGM valve regulated sealing technology;

- High strength ABS material for container & lid;

- Wide temperature scope of application (-15~45℃);

- Best temperature of application (20±5℃);

- No leaking, safe and reliable;

- Standing or lying down for using, convenient to transport and install;

- High sealed reaction efficiency, little loss of water, no need to add distilled water or electrolyte, simple to use and maintain;

- Low self-discharge rate.

**■Specifications**

**Battery Capacity:**

- C10: 40Ah (at 25℃, 10.5V)

- Nominal Capacity (C10): 40Ah (at 25℃, 10.5V); C5: 32Ah (at 25℃, 10.5V)

**Dimension:**

- Length: 196mm

- Width: 165mm

- Height: 170mm

- Total Height: 170mm

**Internal Resistance:** Approximately 8 mΩ (at 25℃)

**Max Short-duration Discharge Current:** 800A (at 25℃)

**Weight:** Approximately 14.59kg

**Terminal:** FP-28/RT-19

**■Charge**

**Using Mode** **Charging Voltage** **Temperature Compensation** **Max Charging Current**

- Standby Use: 2.275±0.025V/cell (at 25℃), Temperature Compensation: -3.3mV/℃/cell, Max Charging Current: 12A

- Cyclic Use: 2.45±0.05V/cell (at 25℃), Temperature Compensation: -5mV/℃/cell

**■Storage**

- Batteries should be stored in a well-ventilated, dry, and clean warehouse;

- Avoid direct sunlight and proximity to heat sources (such as radiators, with a distance greater than 1m);

- Avoid contact with any toxic gases and organic solvents;

- When the ambient temperature is below 25℃, the longest storage life of the battery is 6 months. If the ambient temperature is higher, the longest storage life of the battery will vary as specified in the table below:

  | Storage Temperature (℃) | ≤25  | 26~33 | 34~40 |

  |--------------------------|------|--------|--------|

  | Storage Time (Month)     | 6    | 3      | 1      |

- Batteries should be recharged within the storage life or before use. Charging methods include a maximum charging current of 12A, constant voltage of 2.45±0.05V/cell (at 25℃), charging time of 15~20 hours. The temperature compensation coefficient is -5mV/℃/cell.


INQUIRY