Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

CB12240-CGB battery12V24AH-Suitable for precision instruments

Specifications
- Nominal Voltage: 12V
- Capacity: C20 24Ah (10.5V, at 25℃)
- Nominal Capacity (C20): 24Ah (10.5V, at 25℃); C10 21.6Ah (10.5V, at 25℃)
- Dimension:
- Length: 166mm
- Width: 175mm
- Height: 125mm
- Total Height: 125mm
- Internal Resistance: Approximately 15 mΩ (25℃)
- Max Short-duration Discharge Current: 720A (25℃)
- Weight: Approximately 8.39kg
- Terminal: FP-01/RT-05/RT-26/FO-21

**■Features**

- AGM valve regulated sealing technology;

- High strength ABS material for container & lid;

- Wide temperature scope of application (-15~45℃);

- Best temperature of application (20±5℃);

- No leaking, safe and reliable;

- Can be used standing or lying down, convenient for transportation and installation;

- High sealed reaction efficiency, little water loss, no need to add distilled water or electrolyte, easy to use and maintain;

- Low self-discharge rate.

**■Specifications**

- Nominal Voltage: 12V

- Capacity: C20 24Ah (10.5V, at 25℃)

- Nominal Capacity (C20): 24Ah (10.5V, at 25℃); C10 21.6Ah (10.5V, at 25℃)

- Dimension:

  - Length: 166mm

  - Width: 175mm

  - Height: 125mm

  - Total Height: 125mm

- Internal Resistance: Approximately 15 mΩ (25℃)

- Max Short-duration Discharge Current: 720A (25℃)

- Weight: Approximately 8.39kg

- Terminal: FP-01/RT-05/RT-26/FO-21

**■Charge**

**Using Mode** **Charging Voltage** **Temperature Compensation** **Max Charging Current**

- Standby Use: 2.275±0.025V/cell (25℃), -3.3mV/℃/cell, 7.2A

- Cyclic Use: 2.45±0.05V/cell (25℃), -5mV/℃/cell

**■Storage**

- Batteries should be stored in a dry and clean warehouse with good air ventilation. They should be kept away from direct sunlight and heat sources (such as radiators, with a distance of more than 1 meter). Avoid contact with any toxic gases or organic solvents.

- If the ambient temperature is below 25℃, the longest storage life is 6 months. For higher ambient temperatures, refer to the chart below:

| Storage Temperature (℃) | ≤25   | 26~33 | 34~40 |

|--------------------------|--------|--------|--------|

| Storage Time (Month)     | 6      | 3      | 1      |

- Batteries should be recharged within their storage life or before use. Charging methods involve a maximum charging current of 7.2A, constant voltage of 2.45±0.05V/cell (25℃), with a charging time of 15~20 hours. Temperature compensation coefficient is -5mV/℃/cell.