Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

CB122000B-CGB battery12V200AH-Suitable for precision instruments

SPECIFICATIONS**
Nominal Voltage: 12V
**CAPACITY**
- C10: 200Ah (10.5V, at 25℃)
- Nominal Capacity (C10): 200Ah (10.5V, at 25℃)
- C5: 160Ah (10.5V, at 25℃)
**DIMENSION**
- Length: 520mm
- Width: 260mm
- Height: 208mm
- Total Height: 240mm
**INTERNAL RESISTANCE:** Approx. 4 mΩ (25℃)
**MAX SHORT-DURATION DISCHARGE CURRENT:** 4000A (25℃)
**WEIGHT:** Approx. 73.00kg
**TERMINAL:** FP-08/RT-18

**■FEATURES**

- AGM valve regulated sealing technology;

- High strength ABS material for container & lid;

- Wide temperature scope of application (-15~45℃);

- Best temperature of application (20±5℃);

- No leaking, safe and reliable;

- Standing or lying down for using, convenient to transport and install;

- High sealed reaction efficiency, little loss of water, no need to add distilled water or electrolyte, simple to use and maintain;

- Low self-discharge rate.

**■SPECIFICATIONS**

Nominal Voltage: 12V

**CAPACITY**

- C10: 200Ah (10.5V, at 25℃)

- Nominal Capacity (C10): 200Ah (10.5V, at 25℃)

- C5: 160Ah (10.5V, at 25℃)

**DIMENSION**

- Length: 520mm

- Width: 260mm

- Height: 208mm

- Total Height: 240mm

**INTERNAL RESISTANCE:** Approx. 4 mΩ (25℃)

**MAX SHORT-DURATION DISCHARGE CURRENT:** 4000A (25℃)

**WEIGHT:** Approx. 73.00kg

**TERMINAL:** FP-08/RT-18

**■CHARGE**

**Using Mode** | **Charging Voltage** | **Temperature Compensation** | **Max Charging Current**

--- | --- | --- | ---

Standby Use | 2.275±0.025V/cell (25℃) | -3.3mV/℃/cell | 60A

Cyclic Use | 2.45±0.05V/cell (25℃) | -5mV/℃/cell | 

**■STORAGE**

- Batteries should be stored in a dry and clean warehouse with a good air exchange system. Avoid direct sunlight and proximity to heat sources (such as radiators, maintain a distance of more than 1m). Avoid exposure to toxic gases and organic solvents.

- When the ambient temperature is below 25℃, the longest storage life is 6 months. For higher temperatures, refer to the chart below:

| Storage Temperature (℃) | ≤25 | 26~33 | 34~40 |

|--------------------------|-----|---------|---------|

| Storage Time (Month)     | 6   | 3       | 1       |

- Batteries should be recharged within the storage life or before use. Charging methods: maximum charging current 60A, constant voltage 2.45±0.05V/cell (25℃); Charging time: 15~20 hours; Temperature compensation coefficient: -5mV/℃/cell.


INQUIRY