Welcome: Wuhan CGB Battery System Co., Ltd.
Language: Chinese ∷  English

CB12150-CGB battery12V15AH-Suitable for precision instruments

SPECIFICATIONS
- Nominal Voltage: 12V
- Nominal Capacity (C10): 150Ah (10.5V, at 25℃)
- Nominal Capacity (C5): 120Ah (10.5V, at 25℃)
- Length: 483mm
- Width: 170mm
- Height: 241mm
- Total Height: 241mm
- Internal Resistance: Approximately 4.5 mΩ (25℃)
- Max Short-duration Discharge Current: 3000A (25℃)
- Weight: Approximately 46.3kg
- Terminal: FP-31/RT-32

**■ FEATURES**

- Special formula of grid alloys and lead paste, along with special manufacturing techniques, ensure high quality, high performance, and long lifespan.

- AGM valve regulated sealing technology.

- High-strength ABS material used for container and lid.

- Wide temperature range of application (-15~45℃).

- Optimal operating temperature (20±5℃).

- Leak-free, safe, and reliable.

- Can be used standing or lying down, making them convenient to transport and install.

- High sealed reaction efficiency, minimal water loss, no need to add distilled water or electrolyte, simple to use and maintain.

- Low self-discharge rate.

**■ SPECIFICATIONS**

- Nominal Voltage: 12V

- Nominal Capacity (C10): 150Ah (10.5V, at 25℃)

- Nominal Capacity (C5): 120Ah (10.5V, at 25℃)

- Length: 483mm

- Width: 170mm

- Height: 241mm

- Total Height: 241mm

- Internal Resistance: Approximately 4.5 mΩ (25℃)

- Max Short-duration Discharge Current: 3000A (25℃)

- Weight: Approximately 46.3kg

- Terminal: FP-31/RT-32

**■ CHARGE**

**Using Mode** **Charging Voltage** **Temperature Compensation** **Max Charging Current**

- Standby Use: 2.275±0.025V/cell (25℃), -3.3mV/℃/cell, 45A

- Cyclic Use: 2.45±0.05V/cell (25℃), -5mV/℃/cell

**■ STORAGE**

- Batteries should be stored in a dry and clean warehouse with good air exchange. They should be kept away from direct sunlight and heat sources (such as radiators) by a distance of more than 1m. Batteries should also be kept away from any toxic gases and organic solvents.

- If the ambient temperature is below 25℃, the longest storage life is 6 months. For higher temperatures, the longest storage life varies as shown in the table below:

| Storage Temperature (℃) | ≤25 | 26~33 | 34~40 |

|------------------------|----|-------|-------|

| Storage Time (Month)   | 6  | 3     | 1     |

- Batteries should be recharged within the storage life or before use. The charging method involves a maximum charging current of 45A, constant voltage of 2.45±0.05V/cell (25℃), with a charging time of 15~20 hours and a temperature compensation coefficient of -5mV/℃/cell.